單項(xiàng)選擇題25T型客車檢修規(guī)程規(guī)定,測量AC380V電力配線絕緣電阻值應(yīng)使用()級兆歐表。
A.100V
B.250V
C.500V
D.1000V
您可能感興趣的試卷
你可能感興趣的試題
1.單項(xiàng)選擇題25T型客車檢修規(guī)程規(guī)定,測量DC600V電力配線絕緣電阻值應(yīng)使用()級兆歐表。
A.100V
B.250V
C.500V
D.1000V
2.單項(xiàng)選擇題25T型客車檢修規(guī)程規(guī)定:對于KAX.1型客車行車安全監(jiān)測診斷系統(tǒng)傳感器檢測,制動(dòng)監(jiān)測壓力傳感器在300kPa壓力下,壓力傳感器輸出電流應(yīng)為()
A.3.92~4.05mA
B.5.52~568mA
C.7.12~7.28mA
D.8.72~8.88mA
3.單項(xiàng)選擇題25T型客車檢修規(guī)程規(guī)定:對于KAX.1型客車行車安全監(jiān)測診斷系統(tǒng)傳感器檢測,制動(dòng)監(jiān)測壓力傳感器在200kPa壓力下,壓力傳感器輸出電流應(yīng)為()
A.3.92~4.05mA
B.5.52~5.68mA
C.7.12~7.28mA
D.8.72~8.88mA
4.單項(xiàng)選擇題25T型客車檢修規(guī)程規(guī)定:對于KAX-1型客車行車安全監(jiān)測診斷系統(tǒng)傳感器檢測,制動(dòng)監(jiān)測壓力傳感器在100kPa壓力下,壓力傳感器輸出電流應(yīng)為()
A.3.92~4.05mA
B.552~568mA
C.7.12~7.28mA
D.8.72~8.88mA
5.單項(xiàng)選擇題25T型客車檢修規(guī)程規(guī)定:對于軸溫報(bào)警器的數(shù)字傳感器的檢測,浸水72h后,用500V兆歐表測試絕緣,絕緣電阻須大于()
A.400Ω
B.600Ω
C.800Ω
D.lMΩ
6.單項(xiàng)選擇題25T型客車檢修規(guī)程規(guī)定:對于軸溫報(bào)警器的數(shù)字傳感器的檢測,常態(tài)下用500V兆歐表測試絕緣,絕緣電阻須大于()
A.1MΩ
B.2MΩ
C.5MΩ
D.10MΩ
7.單項(xiàng)選擇題25T型客車檢修規(guī)程規(guī)定:對于軸溫報(bào)警器的控制顯示器檢修,DC110V或DC48V電源電壓在一30%~+25%電壓波動(dòng)范圍內(nèi)控制顯示器須正常工作,整機(jī)顯示溫度與母表偏差為()
A.±2℃
B.±4℃
C.±5℃
D.±6℃
8.單項(xiàng)選擇題25T型客車檢修規(guī)程規(guī)定:對于軸溫報(bào)警器的控制顯示器測試,測試功耗不大于()
A.10W
B.8W
C.6W
D.4W
9.單項(xiàng)選擇題25T型客車檢修規(guī)程規(guī)定:對于空調(diào)試驗(yàn),外溫22℃以上時(shí),運(yùn)轉(zhuǎn)30min之內(nèi),外溫與出風(fēng)口處溫差不大于()
A.12℃
B.l0℃
C.13C
D.15℃
10.單項(xiàng)選擇題25T型客車檢修規(guī)程規(guī)定:對于空調(diào)試驗(yàn),同一接線排各通電接頭溫度差不得高于()
A.20℃
B.25℃
C.30℃
D.35℃
最新試題
什么樣的螺栓需要打防松標(biāo)記,什么樣不需要打防松標(biāo)記?
題型:問答題
簡述內(nèi)部線束六部操作法。
題型:問答題
CRH5型動(dòng)車組有多少節(jié)車廂?每節(jié)都是多長?
題型:問答題
試述軸溫傳感器的種類及其特點(diǎn)。
題型:問答題
客車空調(diào)機(jī)組電氣控制柜有什么特點(diǎn)?
題型:問答題
試述98型應(yīng)急電源應(yīng)急控制系統(tǒng)具有哪些功能?
題型:問答題
CRH5型動(dòng)車組哪些位置必須接地?
題型:問答題
敘述采用集中供電的我國25.5m客車車上配線的結(jié)構(gòu)特點(diǎn)。
題型:問答題
簡述車頂電器連接的操作步驟?
題型:問答題
車體橫向中心線如何確定?
題型:問答題