A. After enabling NPIV, switch interfaces can only be placed into NP, F, or SD modes of operation.
B. NPV devices log in to NPIV devices.
C. NPIV requires the Enterprise License Package.
D. NPIV is supported on the Cisco MDS, N7K, and N5K families of switches.
E. A director class switch should not be placed into NPIV mode.
您可能感興趣的試卷
你可能感興趣的試題
A. B200
B. C210
C. B250
D. C260
E. C460
A. 800 MHz
B. 900 MHz
C. 1066 MHz
D. 1333 MHz
E. 1666 MHz
A. Dual-rank DIMMs are not supported.
B. 16-GB DIMMs are too slow.
C. The largest DIMM an Intel 55xx or 56xx CPU can address is 32 GB
D. The memory bus would be too long.
E. The blade would run too hot.
A. Missing control VLAN in VSM configuration
B. Missing packet VLAN in VSM configuration
C. VSM has no network connection to vCenter
D. VSM extension key is not installed on vCenter
E. vCenter extension key is not installed on VSM
The network administrator is adding a new N1Kv to the vCenter, however, the administrator does not see the new switch under the networking tab of vCenter.
The administrator issues the following command on the VSM to troubleshoot:
VSM# show svs connections
connection VC:
ip address: 10.10.10.30
remote port: 80
protocol: vmware-vim https
certificatE. default
datacenter namE. DC1
DVS uuiD. 67 32 30 50 a6 d2 49 64-9e 1c 5f 49 e3 af 55 99
config status: Disabled
operational status: Disconnected sync status: -
version: -
When attempting to fix the issue, the following error is seen:
VSM-PRI-188# conf
VSM-PRI-188(config)# svs connection VC
VSM-PRI-188(config-svs-conn)# connect
ERROR: [VMWARE-VIM] Extension key was not registered before its use
What is the cause of the error?()
A. Missing control VLAN in VSM configuration
B. Missing packet VLAN in VSM configuration
C. VSM has no network connection to vCenter
D. VSM extension key is not installed on vCenter
E. vCenter extension key is not installed on VSM
Given the following configuration:
port-profile type ethernet DATA-UPLINK
vmware port-group
switchport trunk allowed vlan 1-3967,4048-4093
channel-group auto mode on
no shutdown
state enabled
port-profile type ethernet MGMT-UPLINK
vmware port-group
switchport trunk allowed vlan 10-12
channel-group auto mode on
no shutdown
state enabled
VEMs are seen to be joining and then are lost from the Cisco VSM. How would you resolve this issue?()
A. Remove second NIC from each port profile
B. Remove VEM from VSM (no vem X), remove NICs, and reinsert
C. Ensure that VLANs on uplink profiles are not overlapping
D. Reinstall VEM
E. Issue the command "module vem X execute vemcmd set pinning module vsm 1"
A. Send monitored traffic to a VLAN
B. Send monitored traffic to a remote VEM over L2
C. Receive monitored traffic on a vEthernet interface
D. Send monitored traffic to an IP destination
A. Source and destination interface must be on the same host
B. Source and destination interfaces can be on different hosts
C. Destination vEthernet interface can be on a different VLAN than the source
D. Destination interface can be a physical port
E. Destination interface cannot be a physical port
Given a host with two NICs assigned to a N1k profile,which topologies are suitable for this type of configuration ()
port-profile type Ethernet name VM-Data
vmware port-group
switchport mode trunk
switchport allowed vlan 400-410
channel-group auto mode active
no shut
state enabled
A. Cisco UCS fabric interconnects
B. Pair of N5K’s in VPC
C. Standalone N5K
D. Pair of N5K’s in non-VPC
E. Cisco Catalyst 6000 Switch in VSS
A customer would like to monitor traffic that is being sent to a specific virtual machine named VM001 using SPAN. The customer has another virtual machine configured as a sniffer host called VM002. What configuration is required, and what other changes will need to be made? ()
VSM-PRI-188# sh int vethernet 5
Vethernet5 is up
Port description is VM001, Network Adapter 2
HardwarE. Virtual, address: 0050.56b0.001e (bia 0050.56b0.001e)
Owner is VM "VM001", adapter is Network Adapter 2
Active on module 5
VMware DVS port 484
Port-Profile is VM-vlan-10
Port mode is access
VSM-PRI-188# sh int vethernet 6
Vethernet6 is up
Port description is VM002, Network Adapter 1
HardwarE. Virtual, address: 0050.56b0.0020 (bia 0050.56b0.0020)
Owner is VM "VM002", adapter is Network Adapter 1
Active on module 5
VMware DVS port 485
Port-Profile is VM-vlan-10
Port mode is access
A. Monitor session 1 type span Source interface veth5 both Destination interface veth6 No shut
B. monitor session 1 source vlan 10 destination interface veth6 no shut
C. monitor session 1 type er-span source interface vlan 10 destination ip 10.1.1.10 no shut
D. VM002 must be removed from the Nk1V
E. Move VM002 to Module 5
F. Restart the VEM on module 5
最新試題
In a Cisco Unified Computing System, where are SAN port channels connected to?()
KAL-AP on the Cisco ACE allows communication with Cisco ACE Global Site Selector, to report virtual IP and real server availability. Which statement is true about KAL-AP?()
Which three statements are possible causes for the "fltAdaptorHostIfLink-down" fault in UCS Manager? ()
What is the purpose of this command in a Cisco Application Control Engine?() switch/Admin# show np 1 me-stats "-F0 v"
Where are SAN Port Channel is created in UCS Manager?()
What is the appliance port used to connect to in a Cisco Unified Computing System?()
An administrator creates a vNIC and assigns it to Fabric A with the fabric failover feature enabled. Which statement is true?()
When will an "all configuration" backup be imported into the Cisco UCS Manager?()
Which statements are true regarding the Cisco UCS fabric failover feature? ()
Refer to the exhibit.Your company requires a Cisco UCS configuration that will, at a minimum, allow the configuration in the provided exhibit. Which Cisco UCS components will meet the requirement?()